International NGO · Written recruitment test
Case study
WASH Manager
- Duty station
- Adré, Ouaddaï Province (Chad)
- Time allowed
- 120 min
- Marks
- 100 marks
- Pass mark
- 60 %
- Profile
- Experienced, 5 years or more
Instructions
- The test lasts 120 minutes. It is marked out of 100; the pass mark for the interview is 60.
- Refer to the indicators in the Sphere Handbook 2018 where relevant, and cite them.
- Show all your workings and round up to the next whole number for facilities (latrines, taps).
- Any outside help (another person, artificial intelligence) is forbidden.
- The camp and the data are fictional.
Original practice test, built on the format of written tests used by United Nations agencies and international NGOs. The context and figures are fictitious.
Documents provided
| Item | Value |
|---|---|
| Current population | 14,000 people |
| Population expected in 8 weeks (arrivals ongoing) | 20,000 people |
| Borehole 1 | 12 m³/h pump; safe yield according to the pumping test: 15 m³/h |
| Borehole 2 | 8 m³/h pump; safe yield: 8 m³/h |
| Pumping time | 12 hours per day (one generator); up to 16 hours possible with a second generator |
| Network losses (leaks, broken taps) | Estimated at 15%; 5% achievable after repairs |
| Functional taps | 38 |
| Communal latrines | 120 built, of which 22 full or unusable |
| Handwashing points near latrines | 14 |
| Location | Samples | Free residual chlorine | E. coli (CFU/100 mL) | Turbidity |
|---|---|---|---|---|
| Tank outlets | 4 | 0.3 to 0.4 mg/L | 0 | 2 NTU |
| Taps | 12 | less than 0.2 mg/L: 5; 0.2 to 0.5: 4; more than 0.5: 3 | 0 for 10; 3 and 6 for 2 | 2 to 3 NTU |
| Household storage containers | 10 | 0 mg/L for all 10 | Positive for 8 (10 to 30) | n/a |
Jar test: chlorine demand of the borehole water 1.2 mg/L. Product available: calcium hypochlorite (HTH) with 70% active chlorine. 10 m³ bladder tanks.
| Week | W-3 | W-2 | W-1 | W0 (current) |
|---|---|---|---|---|
| Cases | 12 | 19 | 41 | 77 |
3 positive cholera rapid diagnostic tests this week; culture confirmation pending. The chief of the neighbouring host village complains that his wells have been dropping since borehole 2 opened.
Result
0 out of 100
Mark each answer honestly against the panel's grid: the total is calculated automatically.
Common mistakes that cost marks
- Forgetting network losses and announcing 17 L/p/d instead of 14.6.
- Counting the 120 latrines built instead of the 98 usable ones.
- Concluding that the water is good because it is clean at the tank outlets.
- Forgetting to divide by 0.70 to convert active chlorine into the commercial product.
- Increasing pumping from borehole 2 without measurements, despite the host village's complaint.
Useful references
- Sphere Handbook 2018, WASH chapter: 15 L/p/d, 250 people per tap, distance of less than 500 m, 50 then 20 people per latrine, free residual chlorine at the point of delivery
- World Health Organization, Guidelines for drinking-water quality
- Do no harm principle and conflict sensitivity in water supply interventions